Product Description:
Dental Treatment Chair
Quantity

CREDIA G1

Belmont has been manufacturing dental equipment and selling it worldwide since the 1960s. From the very beginning, we have built a solid reputation for outstanding reliability.


Belmont dental chairs use an electro-hydraulic system that we have been continuously improving since the launch of our first hydraulic chair in 1936. Our chairs have been embraced in many parts of the world thanks to their accurate and smooth operation, their high load capacity, and—above all—their durability. Ergonomically designed, our chairs are built to ensure the comfort of the patient and dentist alike.

Our dental units incorporate a pneumatic system which is simple, durable, and very easy to service. Japanese manufacturing expertise ensures that the valves and fittings work accurately and require very little servicing.

Belmont maintains strict quality control of products and parts, both within the company and in dealings with vendors. The company adopted an established quality management system based on international standards, and this has been transplanted to all of our manufacturing bases around the world.

CHAIR
Various Treatment Positions
  • With a wide range of movement, this chair supports a practical working environment that meets all the operator's requirements.
Smooth Motion and Heavy Lifting Capability
  • The chair's high-quality electro-hydraulic system provides smooth motion while handling patients weighing up to 200 kg.
  • The j.box can be located up to 800 mm in front of the chair.
Hands-Free Operation
  • Hands-free manual chair movement is made possible by a fast-responding foot switch located at the base of the machine. This design eliminates the need for wired foot switches, thereby reducing clutter at the operator's feet and making it easier to clean around the machine.
Flexible and Comfortable Positioning
  • This model features a twin-axis headrest with an elongated post to accommodate taller patients. The flexibility of this dual-articulating system means that the chair can be set up to provide a comfortable seating position for a wide range of patients. It can even be set up backwards for patients in wheelchairs.
Patient Comfort
  • The ergonomic reclining backrest supports the patient in comfort and accommodates natural body movements.
         



OPERATOR'S TABLE
Keep eveything within Arm's Reach
  • The large and spacious tray section has a curved shape that allows you to reach eveything with minimal effort.
Instrument Holders of Universal Size for Easy Handling
  • The instrument holders are designed to stably hold different sizes of instruments.
Minimize Fatigue
  • The rods that holde the handpiecec tubing maintain optimal tension to support the tubing dental procedures. Little effort is required to put the instruments back in the tray. The rods have a smooth surface that is easy to clean.



CUSPIDOR
Easy to Maintain
  • The procelain cuspidor bowl is detachable and easy to clean. Switches to activate cup filling are easily accessible, both for the patient and the assistant.
Assistant Instruments
  • Instrument that assistants can use include a three-way syringe, an HVE, and a saliva ejector with adjustable flow control.
  • A water service outlet with flow control and a toggle switch for flushing the bowl are located on the front panel.
Clinical Flexibility
  • Right or Left Handed.
  • The dentist's section is symmetrically designed and the cuspidor body supports installation for left-handed dentists.
Two Handed or Four Handed
  • A flexible arm enables the assistant's instruments to be positioned conveniently for either two-or-four handed dental work.






DENTAL LIGHT
Easy on the Eyes for Dentist and Patient Alike
  • The Belmont LED light is engineered to minimize eye fatigue. Its crisp, clear edges prevent illumination from bothering the patient's eyes.
  • The 85 mm X 155 mm rectangular light pattern directs the brightest light into the oral cavity, with light gradually becoming less bright across the patient's cheek area.
The Exact Brightness You Need
  • With this in mind, Belmont LED lights include a stepless intensity control to adjust brightness to suit the actual operatory light conditions. Light output can be adjusted between 3,100 lux and 28,000 lux, while maintaining the 5,000 K color temperature that is ideal for shade matching.
Flexibility in Operating Angle
  • The three-axis light head can be rotated smoothly and positioned effortlessly with one hand.
  • Thanks to this flexibility, the user can easily direct illumination to the area it is needed.

STOOL
This stool, which features a backrest with an adjustable angle, can be set up at any height from 473 mm to 623 mm.


UPHOLSTERY COLORS

Credia G1 Upholstery
Dental Chair
Patient capacity 200 kg
Seat 430 mm - 810 mm via electrohydraulic action
Backrest 0° - 73° via electrohydraulic action
Seat angle Fixed at 10°
Armrest Fixed. Long swivel armrest (one side only)
Headrest Double articulating. Manually adjustable
Operation Joystick switch on chair base (Up, Down, Forward, Back) and membrane switch on dental unit (Up, Down, Forward, Back, P1, P2, LP, 0)
Safety lockout switches Safety switch under chair
Safety switch activated by foot control on dental unit
Power input AC 240V; 50 Hz
Weight 225 - 235 kg

Dental Light
Light source Five LEDs
Focal distance 650 mm
Intensity 3100 lux - 28,000 lux
Composite mode 4300 lux
Color temperature 5000 K
Light pattern 85 mm x 155 mm
Operation Sensor

Dental Unit
Delivery type Over the patient using balance arm with manual brake
Umbilical hoses Internal umbilical
Control Pneumatic
Control panel Membrane switches for chair operation (manual and programmed positions)/ Cupfiller switch
Others Handpiece oil mist separator
Transformer 24V/ 4A
Dentist's instruments Three-way syringe
Brushless micromotor up to 40,000 rpm
EMS Piezo Ultrasonic with 1 Scaler Handpiece and 1 Tip A
Cuspidor type of mount  Chair mounted
Cuspidor bowl Detachable, porcelain
Cupfiller Air timer
Bowl flush Controlled with air timer. Linked with cupfiller and activated with toggle on front panel
Light post Straight light post, Ø42.7 mm with hole for monitor bracket and rotatable curved post 
Control panel Water service outlet with flow-adjustable valve
Toggle switch for bowl flush
Water supply City water
Assistant instrument's arm Swing arm and three instrument holders
Vacuum handpiece. Detachable and autoclavable. ID Ø11 mm
SE handpiece. Detachable and autoclavable

Should you need more information on the product, kindly write your details to us.